ALLERGEN TESTING

FOOD ALLERGEN TESTING

We use AgraStrip® allergen test kits from Romer Labs® for most of our customer’s allergen testing needs. They are ready-to-use lateral flow devices designed for both laboratory and on-site testing. Use the menu below to determine if there is a test kit available for the allergen for which you need to test.

Menu of Allergens We Test For:

• What is AgraStrip® ?

The AgraStrip® Allergen lateral flow tests are for the detection of trace amounts of allergens in a low ppm range in the following samples:

  • Raw materials
  • Finished food samples
  • Rinse water (as part of cleaning validation)
  • Environmental swab samples (as part of cleaning validation)

If the sample contains more than 1% (10,000 ppm) allergen, the test will come up negative.

Results are either positive or negative, with the threshold being defined by the detection limit of each allergen type (click on each allergen to obtain the detection limit).  The assay is not designed to quantify the amount of an allergen, the assay is designed to validated the absence of a given allergen in either a product sample or environmental swab.  

• Allergen Testing by MBL or by Customer

The AgriStrip® test kits can be easily implemented into routine analysis as part of an allergen management plan within a HACCP-concept.  The simple test format makes it easy for a smooth workflow to be maintained on-site as well as in the lab.

If you need product tested, we recommend you submit the product to us.  We do not recommend in house testing of products.

 

If you need to validate the absence of allergen post sanitation via rinse water or swab testing, you can do so in house.  The following tabs (① through ⑤) tells you how to conduct testing on swabs.  This information is from the AgraStrip® package inserts © by Romer Labs®.

 

Contact Romer Labs® to set up an account, order your test kits, obtain package inserts, or if you have any questions.

If you conduct your own testing, be sure to record your results.  

1. Important Advice for the Proper Execution of the Test:

 

  • Each AgriStrip® Allergen kit has an extraction buffer which is specific to that kit.  You cannot use the extraction buffer for 1 type of kit for any other type of allergen kit.
  • AgriStrip® Allergen kits including all the reagents should be tempered to room temperature before use; the kits should not be used at refrigeration temperatures.  Otherwise, when not in use, store the kits at the temperature stated by the manufacturer.  
  • Residual sanitizers do not affect the assays.  When testing surfaces for the absence of allergen, it is okay if they are still wet from the sanitation process providing it does not alter the pH outside of the 6-8 range.  
  • Conduct the test in a clean area that is free of the allergen.  
  • It is important to read the results immediately after the 5 minute incubation step since the AgriStrip® test system has been validated extensively and shows reliable results after that exact time.  Longer incubation times can lead to the development of false positive results.
  • The AgriStrip® Allergen lateral flow tests are for the detection of trace amounts of allergens in a low ppm range.  If the sample contains more than 1% (10,000 ppm) allergen, the test will come up negative.
  • Performing the assay in a pH range of 6-8 will lead to reliable results.  Highly acidic samples can lead to false positive results whereas in an alkaline medium there is the tendency to generate false negative results. 

2. Materials Supplied with the Kit

AgraStrip® Kit 1 Tube containing 10 AgraStrip® 1 Dropper Bottle containing 35 mL Extraction Buffer*
10 Incubation Vials 10 Extraction Tubes 10 Tube Caps
10 Extraction Tube Dropper Tips 10 Breakpoint Swabs 1 Tube Holder

3. Sample Preparation – Swab Testing

  1. Fill extraction tube with Extraction buffer to level shown below (blue arrow), take a swab and wet the end by dipping into the buffer.
  1. Wipe an area of 5 cm x 5 cm using side to side movements, rotating the swab tip as you go (the “cross-hatch” swabbing technique indicated below is recommended).
  1. Place the swab into the extraction tube.  Carefully break off the end at the pre-scored point. Leave the swab in this extraction buffer until ready to analyze; analyze within an hour of collecting.
  1. Close the tube with a cap and shake vigorously for 1 minute.
  1. Remove cap from the Extraction Tube and replace with dropper tip and transfer 12 drops (400 µL) to an incubation vial.

4. Assay Procedure

  1. Shake Incubation Vial vigorously by hand for 15 seconds (ensuring liquid comes in contact with the lid of the vial).
  1. Leave incubation vial to stand at room temperature for 5 minutes.
  1. Open the container of AgraStrips®, remove the necessary number of strips and close the tube.  Open the incubation vial and insert the bottom end of the test strip into the vial.

5. Interpretation of Results

Negative Result:

1 Purple line

It is possible that the strip will turn pink during testing. In this case, the test line can appear as a white line on a pink background. This indicates a negative test result, and does not affect the performance of the test.

Positive Result:

2 Purple Lines

The sample contains allergen higher than the cut-off level.

Invalid Result:

No control Line

Regardless of whether the test line appears; repeat the procedure with a new strip.


Special Note for Gluten G12 Testing: